E01

Long Freeze - Long freeze cycle

E02

Long Harvest - Long harvest cycle

E03

Power Loss - Input power supply is interrupted or lost

E04

Hi Cnd Temp/Wtr Cnd Fault - High condenser temperature on air-cooled/water-cooled unit

E05

HPC Fault - High pressure control opened

E06, E13, E14, E17 & E18

Spare - (n/a)

E07

Starving TXV - Starving evaporator for single TXV or low on charge

E08

TXV Fault - Fault in single- or dual-circuit evaporators

E09

Flood Evap 1 - Flooding evaporator fault for single-circuit single evaporator

E10

Flood Evap 2 - Flooding evaporator fault for dual-circuit single evaporator

E11

Refig Fault - Refrigeration system fault (air-cooled and water-cooled units only)

E12

Curtain Fault - Curtain switch is open for more than 24 hours

E15

Low Liq Temp - Low ambient control fault when liquid line temperature drops below 60 degrees Fahrenheit for more than a continuous minute during a freeze cycle

E16

Rmt Cnd Temp - Remote condenser fault when liquid line temperature drops below 40 degrees Fahrenheit or exceeds 140 degrees Fahrenheit for more than a continuous minute during a freeze cycle

E19

ITP Fault - Ice probe fault

E20

WTR Fault - Water system fault

E21

T1 Fault - T1 sensor issue

E22

T2 Fault - T2 sensor issue

E23

T3 Fault - T3 sensor issue

E24

T4 Fault - T4 sensor issue

E25

Bin Prb Fault - Bin level probe low sensor fault

E26

Bin Prb Fault - Bin level probe medium sensor fault

E27

Bin Prb Fault - Bin level probe high sensor fault

E28

AUCS - AuCS board is not connected or present

E29

USB COMM - Communication error caused by defective USB drive or no USB drive detected

E30

USB DNLD - Downloading error caused by defective USB drive

E31

Safe Mode - Machine running in safe mode

E32

RS485 COMM - Event log for when there is no communication between the control board and gateway from the device plugged into the RS485 port

E33

KEYBOARD - Keyboard is faulty or not plugged into the control board

E34

DISPLAY - Keyboard is faulty or not plugged into the control board